Letter Graphics is a leading manufacturer of BCA compliant Statutory Signs. Our extensive knowledge of the Architectural Sign Industry ensures you we supply code compliant signs for all development types. This includes High Rise Residential, Aged Care, Hospitals, Universities, Schools, Tafe’s, Offices, Commercial Buildings and Factories.
Working from a complete set of Architectural Plans, our team puts together a comprehensive signage solution ensuring our works passes inspections by the PCA. With one of the largest ranges of standard statutory signs held in stock, we are able to deliver on short lead time projects. Our in-house manufacturing capabilities mean we offer high quality competitively priced signs. We are often specified by an architect or signage designer within supplied finishes documentation.
Amenities Signs
Braille and Tactile Amenities Signs are required to identify key facilities located within a building. These facilities include Toilets, Showers, Parents Rooms, Change Rooms and Accessible Lifts. Braille and Tactile Signs are referenced in the BCA under section D3.6 and must also comply with AS1428.1 in their design.

Exit Level Signs
Braille and Tactile Exit Level Signs are required to identify all isolated Fire Stairs or Fire Passages within a building. An Exit Level Sign must be clearly visible to a person approaching the exit, as referenced in the BCA under section E4.5 and must also comply with AS1428.1 in their design. These signs are installed in conjunction with “FIRE SAFETY DOOR” and “OFFENCES RELATING TO FIRE EXITS” signs required on fire rated egress doors.

Fire Safety Door Signs
Statutory Signs are required on all new developments to alert persons that the operation of certain doors must not be impaired. Fire Safety Door Signs are referenced in the BCA under section D2.23 and apply to horizontal exit doors, fire isolated doors and smoke doors. Minimum uppercase text height of 20 mm applies and the text colour must contrast the background colour. These signs are in addition to “EXIT LEVEL SIGNS” and “OFFENCES RELATING TO FIRE EXITS” required on fire rated egress doors.

Fire Equipment Signs
Doors for all Fire Equipment cupboards need to be clearly identified with a Code Compliant Sign. Minimum uppercase text heights (various) apply and the text colour must contrast the background colour and comply with AS 2419.1.
Common Fire Equipment Signs include:
- FIRE HYDRANT BOOSTER
- FIRE SPRINKLER BOOSTER
- FIRE HOSE REEL
- FIRE EXTINGUISHER
- BOOST & TEST PRESSURE
- BLOCK PLANS
- FIRE PUMP ROOMS
- RELAY WARNING